Avaya DEFINITY Server CSI Maintenance Manual page 932

Table of Contents

Advertisement

Maintenance Objects
Table 164. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Test
Code
Result
1003
ABORT
1004
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
932
Issue 5 October 2002
Description/ Recommendation
The system could not allocate a tone receiver for the test. The system may
be oversized force.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV
Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT
Maintenance documentation.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the trunk
group/member number of the port. Use status trunk to determine the
service state of the port. If the service state indicates that the port is in use,
the port is unavailable for certain tests. Wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
The test was disabled via administration. Verify that the
field on the Trunk Group screen is set to n. To enable the test, issue
Test
change trunk-group x where x equals the number of the trunk group to be
tested. Set the 'Maintenance Test' field y.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Response to the test was not received within the allowable time period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Maintenance
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents