Maintenance Objects
Table 355. TEST #1379 Ping Test — Continued
Error
Test
Code
Result
7, 89,
FAIL
1007
PASS
NT Reset Test (#1381)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
Table 356. TEST #1381 NT Reset Test
Error
Test
Code
Result
Description/ Recommendation
None
ABORT
System resources required for this test are not available.
1015
ABORT
Port is not out-of-service.
2100
ABORT
System resources required for this test are not available.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1384
Issue 5 October 2002
Description/ Recommendation
Ping to the destination failed through this port due to the destination
down.
1. Verify that at least one destination reachable through this port is
up.
2. Once verified, execute test port UUCSSpp command to verify
that the H.323 Signaling Group Ping Test (#1387) passes.
Ping through this port successful.
1. Retry the reset board UUCSS command at 1-minute intervals a
maximum of 5 times.
1. Busyout the circuit pack (busyout board UUCSS).
2. Execute the reset board UUCSS command again.
1. Retry the reset board UUCSS command at 1-minute intervals a
maximum of 5 times.
1. Execute the reset board UUCSS command again.
2. If the problem persists, replace the circuit pack.
Continued on next page
Continued on next page
Need help?