Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time slot information and sanity audit is
performed on the DTMR port.
Table 247. TEST #43 Tone Detector Audit/Update Test
Error
Test
Code
Result
ABORT
2000
ABORT
2100
ABORT
FAIL
PASS
1150
Issue 5 October 2002
Description/ Recommendation
The system was not able to allocate all the resources needed for this test.
1. Wait one minute and try again.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Hardware audit failed.
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity is reduced. In order to restore the system performance to
normal, replace the Tone Detector circuit pack containing the defective
DTMR port.
The DTMR port has been successfully refreshed with its translation.