Avaya DEFINITY Server CSI Maintenance Manual page 1538

Table of Contents

Advertisement

Maintenance Objects
Table 426. RISC Processor Circuit Pack Error Log Entries — Continued
Error
Aux
Type
Data
1025(b)
Any
1281
Any
1793(c)
2049(d)(e
Any
)
1.
The MTP Reset Test (#101) logs you off. The MTP Dual Port Ram Test (#104) can also log you off.
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. The BOOTPROM Checksum Test (#80) failed. Refer to the FAIL condition
of this test for further action.
b. A parity error was detected in the processor's data cache or instruction
cache. Aux Data indicates the difference in the number of parity errors
since the last report.
c. The Processor Bus Time-out Test (#82) failed. Refer to the FAIL condition
of this test for further action.
d. Aux Data of 100 is an LMM initialization failure.
e. The Processor Sanity Timer Test failed during a reset level 4 or 5
initialization. reset system 4 at the customers convenience and if the alarm
occurs again, replace the Processor circuit pack. The system runs with this
failure, but it is not protected if the system software has a sanity problem.
The test processor a long clear command clears this alarm, but the sanity
timer is only tested during initialization so the alarm occurs again and the
system is not protected against insane software.
1538
Issue 5 October 2002
Associated Test
Processor Cache Audit
(#896)
Processor Cache
Test(#895)
Processor Bus
Time-out Exception
Test (#82)
Processor Sanity Timer
Test
Alarm
On/Off
Level
Board
MINOR
ON
MAJOR
ON
MAJOR
ON
MINOR
ON
1
Test to Clear Value
test processor a r 2
test processor a r 1
test processor a r 2
test processor a l c
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents