Avaya DEFINITY Server CSI Maintenance Manual page 1167

Table of Contents

Advertisement

ETH-PT (Control LAN Ethernet)
Error Log Entries and Test to Clear Value
Table 255. ETH-PT Error Log Entries
Aux
Error Type
Data
1
0
0
1 (a)
0
513 (b)
0
769 (c)
0
1281 (d)
0
1537, 1538
(e)
1793-1920
(f)
2305-2560
(g)
2561-2816
(g)
3329 (h)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 1: Ethernet Local Looparound Test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
b. Error Type 513: Link Integrity Inquiry Test (#1282) failed or CLAN port
detected loss of Ethernet link integrity.
Possible causes:
1. Test the port (test port UUCSSpp long).
2. If the Link Integrity Inquiry Test (#1282) fils, refer to its repair
555-233-119
Associated Test
Any
Ethernet Local
Looparound
Test (#1278)
Link Integrity Inquiry
(#1282)
Session Status Test
(#1286)
TCP/IP Ping Test
(#1281)
Cabling
Ethernet transceiver
procedure.
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
MINOR
OFF
WNG
OFF
MINOR
OFF
WNG
OFF
Issue 5 October 2002
Test to Clear Value
test port UUCSSpp s
test port UUCSSpp l r 3
test port UUCSSpp r 2
Continued on next page
1167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents