Suzuki SX4 Service Manual page 808

Hide thumbs Also See for SX4:
Table of Contents

Advertisement

5A-108 Automatic Transmission/Transaxle:
16) Remove valve body harness (1).
CAUTION
!
When pulling valve body harness out of
transaxle case, take care not to damage
transmission fluid temperature sensor (2) at
narrow exit of case.
Careless sensor treatment might cause
sensor malfunction.
17) Remove governor apply No.1 gasket (1).
18) Remove cooler check valve (1) and spring (2).
19) Remove accumulator pistons and springs.
To remove C2 (1), C1 (2) and B1 (3) accumulator
pistons and springs, position rag on pistons to catch
each piston. To remove pistons, force low-pressure
compressed air (1 kg/cm
hole (4) as shown in figure, and pop each piston into
rag.
NOTE
Do not push accumulator pistons with
fingers or anything before removing them.
Pushing them may cause compressed fluid
in accumulator to spew out of hole and get to
your face and clothes.
I2RH0B510091-01
I2RH0B510092-01
I2RH0B510093-01
2
, 15 psi, 100 kPa, max) into
I2RH0B510094-01

Advertisement

Table of Contents
loading

Table of Contents