8B-23 Air Bag System:
Troubleshooting
Step
1
"AIR BAG" warning light check
1) Turn ignition switch to ON position.
Does "AIR BAG" warning light come ON steady?
2
Scan tool condition check
1) Make sure that SUZUKI scan tool is as follows.
• Correct PCMCIA card (software) is used.
• There are no deformation and wear for DLC cable
terminals.
• Connection for DLC cable terminals is in good
condition.
Are they OK?
3
Scan tool operation check
1) Check DLC terminal for deformation and wear.
2) If it is in good condition, connect SUZUKI scan tool to
DLC with ignition switch turned OFF.
3) Check if communication is possible by making
communication with other control modules (BCM, ABS
control module, HVAC control module (auto A/C model)
or P/S control module).
Is it possible to communicate with the other control
modules?
4
Serial communication circuit check
1) With ignition switch turned OFF, disconnect SDM
connector "L04" and check for proper connection at
SDM connector terminal.
2) If connections are OK, check that "Serial data circuit" is
as follows.
• Wiring resistance of "Serial data circuit" wire between
DLC and SDM connector is less than 1 Ω.
Is it resistance less than 1
5
SDM power and ground circuit check
1) Check power supply circuit and ground circuit for SDM
referring to "SDM Power Supply and Ground Circuit
Check".
Is check result in good condition?
6
DLC power and ground circuit check
1) Check power supply circuit and ground circuit for DLC as
follows.
• Voltage of "DLC power supply circuit" between DLC
terminal and vehicle body ground is 10 – 14 V with
ignition switch turned ON.
• Wire resistance of each "DLC ground circuit" between
DLC terminal and vehicle body ground is less than
1Ω.
Is check result in good condition?
Action
?
Yes
Go to ""AIR BAG"
Warning Light Comes
ON Steady".
Go to Step 3.
Go to Step 4.
Go to Step 5.
Substitute a known-
good SDM and recheck.
Go to Step 7.
No
Go to Step 2.
Repair or replace
defective part.
Go to Step 6.
"Serial data circuit" is
open or high resistance.
Repair or replace
defective circuit.
Repair or replace
defective circuit.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SX4 and is the answer not in the manual?

Questions and answers

Gawthorpe
February 27, 2025

Adjust throttle motor

1 comments:
Mr. Anderson
February 27, 2025

The idle speed on a Suzuki SX4 should be controlled by the Idle Air Control Valve (IACV) rather than adjusting the idle screw on the throttle body, as the screw is factory set. Before using compressed air in the idle-air-bypass passages, the IACV should be removed to prevent damage to its delicate mechanism. If there is an issue with idle speed, checking the IACV function and referring to the SX4 service manual is recommended.

This answer is automatically generated

Adetunji Ismail
March 4, 2025

I have an issue of crank but not starting When I scan it brought this codeU0100 Which means no communication thou crank sensor wire was cut off but it was fix back What could be wrong and what could be the solution,

User image 67c6e55d91ac0
jack wrona
March 6, 2025

increasing revs when changing gears

1 comments:
Mr. Anderson
March 6, 2025

The Suzuki SX4 may have increasing revs when changing gears due to its drive-by-wire system and the difference in final drive ratios between the manual (4.41) and automatic (2.81) transmissions. This difference causes high cruising RPMs in the manual version and sluggishness in the automatic. Additionally, if the revs climb while going uphill, it may be due to the transmission downshifting or kicking out of overdrive. Other possible causes include low transmission fluid, abuse, or a faulty transmission design.

This answer is automatically generated

paul murphy
March 19, 2025

My heater stopped working the blower **** is good, control unit ?

1 comments:
Mr. Anderson
March 19, 2025

Possible issues with the heater in a Suzuki SX4 if the blower is working but the heater is not include:

1. Incorrect Temperature Output
- Temperature control cable broken or bent (non-A/C and manual A/C) → Check the temperature control cable.
- Temperature selector faulty (non-A/C and manual A/C) → Check the temperature selector.
- Incorrect installation of the temperature control cable (non-A/C and manual A/C) → Check and adjust the position as necessary.
- Temperature control door assembly broken → Repair the temperature control door assembly.
- Air ducts clogged → Repair air ducts.
- Heater core leaked or clogged → Replace the heater core.
- Heater hoses leaked or clogged → Replace heater hoses.
- Thermostat faulty → Check the thermostat.
- Temperature control actuator faulty (auto A/C) → Check the temperature control actuator.
- HVAC control module faulty (auto A/C) → Check the HVAC control module.
- Wiring or grounding faulty (auto A/C) → Repair as necessary.

2. Other Possible Causes
- Air flow control cable broken or bent → Check the air flow control cable.

Checking and addressing these components should help identify and resolve the heater issue.