8B-37 Air Bag System:
DTC Troubleshooting
Step
1
Was "Air Bag Diagnostic System Check Flow" performed?
2
Driver air bag circuit check
1) With ignition switch turned OFF, disconnect contact coil
connector "G347" located under the steering column.
2) Disconnect SDM connector "L04".
3) Check for proper connection to contact coil connector at
terminal in "G347" connector.
4) Check for proper connection to SDM connector at
terminal "L04-3" and "L04-4".
5) If OK, release shorting bar in SDM connector inserting
release tool (1) included in special tool (A).
Special tool
(A): 09932–76010
6) With ignition switch turned ON, measure voltage
between "G347-1" terminal and body ground, and
between "G347-2" terminal and body ground.
"L04-3"
1,(A)
Is each measured voltage 0 V?
3
Floor harness circuit check
1) Disconnect "L378" connector located near the driver side
front pillar lower trim.
2) If OK, release shorting bar in SDM connector inserting
release tool (1) included in special tool (A).
Special tool
(A): 09932–76010
3) With ignition switch turned ON, measure voltage
between "L378-1" terminal and body ground, and
between "L378-2" terminal and body ground.
"L04-3"
1,(A)
Is each measured voltage 0 V?
Action
"L04-4"
(A)
"L04-4"
(A)
Yes
Go to Step 2.
Go to Step 4.
I7RW01821022-01
Repair "GRN/RED"
circuit or "GRN" circuit
for short to power
supply circuit at
instrument panel
harness.
I7RW01821022-01
No
Go to "Air Bag
Diagnostic System
Check Flow".
Go to Step 3.
Repair "GRN/RED"
circuit or "GRN" circuit
for short to power
supply circuit at floor
harness.
Need help?
Do you have a question about the SX4 and is the answer not in the manual?
Questions and answers
Adjust throttle motor
The idle speed on a Suzuki SX4 should be controlled by the Idle Air Control Valve (IACV) rather than adjusting the idle screw on the throttle body, as the screw is factory set. Before using compressed air in the idle-air-bypass passages, the IACV should be removed to prevent damage to its delicate mechanism. If there is an issue with idle speed, checking the IACV function and referring to the SX4 service manual is recommended.
This answer is automatically generated
I have an issue of crank but not starting When I scan it brought this codeU0100 Which means no communication thou crank sensor wire was cut off but it was fix back What could be wrong and what could be the solution,
increasing revs when changing gears
The Suzuki SX4 may have increasing revs when changing gears due to its drive-by-wire system and the difference in final drive ratios between the manual (4.41) and automatic (2.81) transmissions. This difference causes high cruising RPMs in the manual version and sluggishness in the automatic. Additionally, if the revs climb while going uphill, it may be due to the transmission downshifting or kicking out of overdrive. Other possible causes include low transmission fluid, abuse, or a faulty transmission design.
This answer is automatically generated
My heater stopped working the blower **** is good, control unit ?
Possible issues with the heater in a Suzuki SX4 if the blower is working but the heater is not include:
1. Incorrect Temperature Output
- Temperature control cable broken or bent (non-A/C and manual A/C) → Check the temperature control cable.
- Temperature selector faulty (non-A/C and manual A/C) → Check the temperature selector.
- Incorrect installation of the temperature control cable (non-A/C and manual A/C) → Check and adjust the position as necessary.
- Temperature control door assembly broken → Repair the temperature control door assembly.
- Air ducts clogged → Repair air ducts.
- Heater core leaked or clogged → Replace the heater core.
- Heater hoses leaked or clogged → Replace heater hoses.
- Thermostat faulty → Check the thermostat.
- Temperature control actuator faulty (auto A/C) → Check the temperature control actuator.
- HVAC control module faulty (auto A/C) → Check the HVAC control module.
- Wiring or grounding faulty (auto A/C) → Repair as necessary.
2. Other Possible Causes
- Air flow control cable broken or bent → Check the air flow control cable.
Checking and addressing these components should help identify and resolve the heater issue.
This answer is automatically generated