Sign In
Upload
Manuals
Brands
Avaya Manuals
Server
DEFINITY Server R
Avaya DEFINITY Server R Manuals
Manuals and User Guides for Avaya DEFINITY Server R. We have
1
Avaya DEFINITY Server R manual available for free PDF download: Manual
Avaya DEFINITY Server R Manual (550 pages)
Upgrades and Additions
Brand:
Avaya
| Category:
Motherboard
| Size: 11 MB
Table of Contents
Table of Contents
5
About this Book
9
Offer Categories
9
Conventions Used in this Book
10
How to Get this Book
12
How to Get Technical Assistance
13
Security
14
Antistatic Protection
14
Remove/Install Circuit Packs
14
Trademarks
14
Tell Us What You Think
15
1 Upgrading Release 9/10R to Avaya
17
DEFINITY Server R Running
17
Avaya Communication Manager
17
Read this First
17
TN1650B Memory Circuit Pack
17
Task Table
19
Table of Contents
20
Pre-Upgrade Checklist
21
Task Description Page
21
System Identification (SID) Number
22
Switch Configuration File
24
Duplicate System Software
32
Verify System Status
32
Check Clock Synchronization
33
Check for Translation Corruption
33
Check Link Status
33
Record All Busyouts
33
Check SPE
34
Save Translations to Disk Drive (Pre-Upgrade)
34
Save Translations to Removable Media (Pre-Upgrade)
34
Verify Software Versions and Translation Timestamp
34
Disable Scheduled Maintenance and Alarm Origination
35
Busyout MMI Circuit Packs
36
Upgrade the Software
36
Install the License File
37
Administer No-License/Emergency Numbers
38
Set Daylight Savings Rules
39
Release MMI (High/Critical Reliability Only)
40
Set Core Dump Vector (H/C Only)
40
Set Locations (if Necessary)
40
Check for Translation Corruption
41
Verify the Upgrade
41
Enable Scheduled Maintenance
42
Register the Switch for Maintenance
42
Save Announcements to Removable-Media
42
Save Translations to Removable-Media
42
Save Translation to Back up Disk
46
Save Translations to Disk
46
2 Upgrading G3Rv4 and R5/6/7/8R to
49
Avaya DEFINITY Server R Running
49
Avaya Communication Manager
49
Required Hardware
49
Hardware Replacement
50
Read this First
50
Remote Feature Activation (RFA)
50
TN2211 Optical Drive
52
Task Table
53
Table of Contents
54
Phase 1 Hardware Replacement
57
Display Alarms
67
Duplicate System Software
67
Record Busyouts
67
Check Clock Synchronization
68
Check for Translation Corruption
68
Check Link Status
68
Check SPE
69
Save Translations to Disk Drive (Pre-Upgrade)
69
Save Translations to Tape/Removable Media (Pre-Upgrade)
69
Verify Software Versions
69
Busyout MMI Circuit Packs (High/Critical Reliability Only-If Necessary)
70
Disable Scheduled Maintenance and Alarm Origination
70
Set SPE a and Tone/Clock a to Active (High/Critical Reliability Only)
71
Remove the UN332B and Tape Drive
72
Tape Drive: Lock to SPE a (High/Critical Reliability Only)
72
Tape Drive: Power down SPE B
72
Install the UN332C and Optical Drive
73
Optical Drive: Power up SPE B
75
Optical Drive: Unlock DUPINT Switches (High/Critical Reliability Only)
75
Optical Drive: Wait for System to Refresh (High/Critical Reliability Only)
76
Set SPE B and Tone-Clock B to Active (High/Critical Reliability Only)
76
Install the UN332C and Optical Drive
77
Remove the UN332B and Tape Drive
77
Tape Drive: Lock to SPE B (High/Critical Reliability Only)
77
Tape Drive: Power down SPE a
77
Optical Drive: Power up SPE a
78
Optical Drive: Unlock DUPINT Switches (High/Critical Reliability Only)
78
Optical Drive: Wait for System to Refresh (High/Critical Reliability Only)
78
Save Announcements (if Necessary) to Removable Media
79
Phase 2 Hardware Addition/Replacement
80
Save Translations to Removable Media
79
Verify Software Version
79
Verify Translation Timestamp
80
Lock to SPE B (High/Critical Reliability Only)
81
Verify Active Tone-Clock Is on SPE B (High/Critical Reliability Only)
81
Add Memory, Replace DUPINT Circuit Pack, and Unseat Disk Drive on
82
Power down SPE a
82
Power up SPE a
83
Unlock DUPINT Switches (High/Critical Reliability Only)
83
Wait for System Handshake (High/Critical Reliability Only)
83
Lock Switches to SPE a (High/Critical Reliability Only-Affects Service)
84
Power down SPE B (High/Critical Reliability Only)
84
Set Tone-Clock in SPE a to Active (High/Critical Reliability Only)
84
Add Memory, Replace DUPINT Circuit Pack, and Unseat Disk Drive on
85
Power up SPE B (High/Critical Reliability Only)
85
Install the License File
86
Unlock DUPINT Switches (High/Critical Reliability Only)
86
Wait for System Refresh (High/Critical Reliability Only)
86
Administer No-License/Emergency Numbers
87
Set Daylight Savings Rules (if Necessary)
88
Release MMI (High/Critical Reliability Only)
89
Set Locations (if Necessary)
89
Check for Translation Corruption
90
Check ISDN Signaling Group States
90
Check Link Status
90
Enable Scheduled Maintenance
90
Install V9 or Later Disk Drive(S)
91
Restore Disk
93
Save Announcements Removable-Media (if Necessary-Post-Upgrade)
93
Save Translations Removable-Media (Post-Upgrade)
93
Enable Alarm Origination to INADS
94
Register the Switch for Maintenance
94
Check Customer Options
97
Save Translations (Post-Upgrade)
97
Affix Position Label(S)
98
Back up Disk
98
Busy out Trunks
98
Resolve Alarms
98
Return Replaced Equipment
98
Set Core Dump Vector
98
Verify Survivable Remote Epns
98
3 Upgrading G3Vs to an Avaya DEFINITY Server R Running Avaya Communication Manager
99
Read this First
100
Task Tables/Set Locations
102
Set Locations
102
Software Upgrade
102
Task List
102
Task Tables
102
Perform Pre-Cutover Procedures
103
Check SPE
108
Remove the Present System
108
Check Link Status
109
Disable Maintenance
109
Save Translations
109
Back up Disk
110
Check ISDN Signaling Group States
110
Save Announcements
110
Shut down DEFINITY LAN Gateway System
110
Install Emergency Transfer Ground Wire
111
Power down the SPE
111
Shut down DEFINITY AUDIX System (if Necessary)
111
Install the MCC1 Cabinets
112
Power-Up the MCC1 PPN
112
Remove Emergency Transfer Ground Wire
112
Remove the Present System
112
Unpack and Install the Cabinet
112
Install the License File
113
Administer No-License/Emergency Numbers
114
Restore Disk
114
Verify Software Version
114
Set Daylight Savings Rules
115
Re-Record Announcements (if Necessary)
116
Rerecord Announcements
116
Check Link Status
117
Complete the Upgrade
117
Copy Announcements (if Necessary)
117
Install Remaining Hardware and Administer the System
117
Resolve Alarms
117
Check ISDN Signaling Groups
118
Enable Alarm Origination to INADS
118
Enable Scheduled Maintenance
118
Register the Switch for Maintenance
118
Check Customer Options
122
Power up DEFINITY AUDIX System
122
Power up DEFINITY LAN Gateway System
122
Save Announcements (if Necessary)
122
Save Translations
122
Verify the Upgrade
122
Back up Disk
123
DEFINITY AUDIX Power Procedures
123
Return Replaced Equipment
123
Set Core Dump Vector
123
Upgrading R5Si/R6Si to an Avaya DEFINITY Server R EPN Running Avaya Communication Manager
125
Read this First
126
Relocation of Port Circuit Packs
127
Task Tables/Required Tools
131
Required Tools
131
Task Tables
131
Preliminary Procedures
133
Retranslate Port Circuits
133
Before Starting the Upgrade, Have the Items Listed in Table 3-2 Ready or
134
Pre-Upgrade Checklist
134
Follow Routine Preventive Maintenance
138
Label Cables
138
Check SPE
139
Disable Scheduled Maintenance and Alarm Origination to INADS
139
Dismantle SCC PPN
139
Busyout MMI Circuit Packs (H/C Only)
140
Save Announcements (if Necessary)
140
Save Translations
140
Check Link Status
141
Convert to SCC EPN
141
Shut down DEFINITY LAN Gateway System
141
Power down Existing System
142
Shut down DEFINITY AUDIX System
142
Disconnect Equipment and Cables
143
Disconnect Power and Ground
143
Disconnect TDM/LAN Cables and ICC Cables
143
Install Emergency Transfer Ground Wire
143
Remove Circuit Packs
143
Install Circuit Packs
144
Install Port Cabinets
144
Install the EPN
144
Remove the Existing Control Cabinet
144
Unpack and Install Expansion Control Cabinet
144
Change Cabinet Address Plugs
145
Install TDM/LAN Bus Terminators
147
TDM/LAN Bus Terminators
147
Connect TDM/LAN Cables and ICC Cables
149
Connect Power and Ground
151
Install System Access Ports
151
Interconnect Port Networks
151
Verify Usable Circuit Pack Vintages
151
Reboot the System
152
Remove Emergency Transfer Ground Wire
152
Reseat DEFINITY AUDIX System
152
Reseat DEFINITY LAN Gateway System
152
Install the License File
153
Administer No-License/Emergency Numbers
154
Label Main Distribution Frame
154
Reconnect Cables
154
Restart DEFINITY LAN Gateway System
154
Install Rear Ground Plates (Systems with Earthquake Protection)
155
Power up the EPN Cabinet
155
Install Front Ground Plates (Systems with Earthquake Protection)
156
Install Cabinet Clips (Systems Without Earthquake Protection)
157
Interconnect Port Networks with Fiber Optic Cabling
164
Table of Contents
166
Carefully Attach the Fiber Optic Cable (with Cable Ties) to the Rear Covers of the EPN Stack
170
Connect the Other End of the Fiber Optic Cable from the PPN to the Lightwave Transceiver at Slot 2A01
170
Coil up the Surplus Length of Fiber Optic Cable, and Place the Coil
180
Either in the Cable Manager or on the Bottom Shelf
180
Power Supply) of the PPN Cabinet
180
DEFINITY AUDIX Power Procedures
189
Upgrading a Multicarrier G2
191
Universal Module to Avaya DEFINITY Server R EPN Running Avaya Communication Manager
191
Read this First
192
Single-Mode Fiber Attenuators
192
Preliminary Procedures
199
Task Tables
200
Task Description
201
Standard Reliability
204
Process
209
Remove Module Control Carrier(S)
210
Install Expansion Control Carrier(S)
216
Complete the Upgrade
219
Power up the EPN Cabinets
223
Reconnect Cables to Upgraded EPN Cabinet
223
Retranslate Port Circuits
223
Check Link Status
224
Enable Alarm Origination to INADS
224
Enable Scheduled Maintenance
224
Register the Switch for Maintenance
224
Resolve Alarms
224
Back up Disk
228
Check Customer Options
228
Save Translations
228
Interconnect Port Networks
219
High Reliability
229
High Reliability
231
Follow Routine Preventive Maintenance
233
Preventive Maintenance
233
Remove Module Control Carrier(S)
234
Install Power-Failure Transfer Ground Wire
234
Power down G2 System
234
Remove Circuit Packs from Module Control Carrier a
235
Remove CURL from Module Control Carrier a
235
Remove Module Control Carrier a
235
Install Expansion Control Carrier(S)
239
Install New Expansion Control Carrier a
239
Unpack and Inspect Expansion Control Carrier
239
Complete the Upgrade
243
Remove Power-Failure Ground Wire
243
Interconnect Port Networks
243
Boot the System
244
Install the License File
244
Set Additional Administration
247
Register the Switch for Maintenance
249
Back up Disk
252
Critical Reliability
253
Pre-Upgrade Checklist
253
Upgrade Cabinets
257
Remove Module Control Carrier(S)
259
Check Link Status
259
Follow Routine Preventive Maintenance
259
Label Cables
259
Power down G2 System
259
Disconnect Cables
260
Install Power-Failure Transfer Ground Wire
260
Remove Circuit Packs from Module Control Carriers a and B
260
Remove CURL from Module Control Carrier a
261
Remove Module Control Carriers a and B
261
Install Expansion Control Carrier(S)
265
Prepare the New a and B Position Carriers
265
Install the New a and B Position Carriers
266
ICC Connections
270
Interconnect Port Networks
272
Install Circuit Packs
272
Test the CURL
272
Complete the Upgrade
273
Boot the System
273
Install the License File
273
Remove Power-Failure Ground Strap
273
Verify Usable Circuit Pack Vintages
273
Administer No-License/Emergency Numbers
275
Set Daylight Savings Rules
275
Set Additional Administration
276
Close Upgraded EPN Cabinet and Reconnect Cables
277
Power up the EPN Cabinets
277
Retranslate Port Circuits
277
Check Link Status
278
Interconnect Port Networks with Fiber Optic Cabling
282
Continued on Next Page
231
6 Adding New Carriers and EPN Cabinets
317
Add MCC Port Carriers
318
Add a Control Carrier (Add Duplication)
330
TDM/LAN Connections for Standard-Reliability PPN
334
Add the Fiber Optic Cable
349
Single-Mode Fiber
356
Add Center Stage Switch
363
Add a Switch Node Carrier
368
Switch Node Carrier
379
TDM/LAN Connections for PPN
379
Install a New EPN Cabinet in an Existing System
392
Remove an EPN Cabinet from an Existing System
404
DEFINITY AUDIX Power Procedures
410
7 Adding or Removing Cabinet Hardware
411
Add Circuit Packs
411
List of Circuit Packs
412
Radio Controller
414
Upgrade Firmware on Programmable Circuit Packs
416
Programmable Circuit Packs
416
Procedure
418
Self Download
418
Installing TN464GP/TN2464BP with Echo Cancellation
433
Add CO, FX, WATS, and PCOL
435
Add DID Trunks
436
Add Tie Trunks
436
Tie Trunk
437
Add DS1 Tie and OPS
438
Add Speech Synthesis
438
Add Code Calling Access
438
Add Pooled Modem
439
Add Multiple Integrated Announcement Circuit Packs
440
Add ISDN-PRI
452
Add Callvisor ASAI
453
Add DCS Interface
455
Add TTC Japanese 2-Mbit Trunks
455
Add ISDN-BRI
458
Add External Modem to EPN
459
Add Radio Controller
459
Add IP Solutions
460
Remote Office
460
Installing an Integrated Channel Service Unit (ICSU) Module
504
Installing a 3150/3170 Channel Service Unit
509
Fiber Link Administration
511
Administer Fiber Links
511
Troubleshooting an Upgrade
529
You Can Help
529
Troubleshooting Guidelines
529
Troubleshooting License File Problems
536
Software Upgrade
541
Where to Get Additional Help
542
Access Security Gateway
543
Using the ASG Mobile
544
Index
545
Advertisement
Advertisement
Related Products
Avaya Definity Enterprise Communications Server
Avaya DEFINITY Server CSI
Avaya DEFINITY ECS
Avaya Definity SI
Avaya DEFINITY SERIES
Avaya Definity G3 / ProLogix
Avaya Comdial DXP 7042
Avaya IP Office HP DL360G7
Avaya IP Office HP DL120G7
Avaya Definity Callmaster II
Avaya Categories
IP Phone
Telephone
Server
Switch
Gateway
More Avaya Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL