Maintenance Objects
Hardware Error Log Entries and Test to Clear
Values
Table 76. ATM D-channel Error Log entries
Error
Aux
Type
Data
Associated Test
0 (a)
0
Any
18 (b)
0
busyout port UUCSSpp
130 (c)
None
1793
Signaling Link Board
(d)
Check (#643)
1.
pp is for ports 9-32.
Notes:
a. Run the Short Test Sequence first. If all tests pass, run the Long Test
Sequence. Refer to the appropriate test description and follow the
recommended procedures.
b. Error Type 18: D-channel busied out; no calls possible over this D-channel.
c. Error Type 130: circuit pack removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
d. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
Check (#643). Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH maintenance object is test port UUCSSpp,
where pp is for ports 9-32.
Table 77. System Technician-Demanded Tests: ATM-DCH
Order of Investigation
Signaling Link Board Check (#643)
D = Destructive, ND = Nondestructive
1.
742
Issue 5 October 2002
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
Short Test
Long Test
Sequence
Sequence
X
X
Test to Clear Value
1
test port UUCSSpp
release port UUCSSpp
test port UUCSSpp
test board UUCSS l
Continued on next page
D/ND1
ND
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?