disable-autosync

Syntax
Release Information
Description
Mode
516
[ no ] disable-autosync
Command introduced before JunosE Release 7.1.0.
Halts automatic synchronization between the primary and standby SRP modules. When
high availability is enabled (that is, the high availability state is initializing, active, or
pending) this command affects only changes to nonconfiguration files. With high
availability enabled, configuration changes are always mirrored to the standby SRP
module. The no version restores the default situation, in which automatic synchronization
runs as a background process every 5 minutes.