JunosE 11.3.x Command Reference Guide A to M

bulkstats collector

Syntax
Release Information
Description
Options
Mode
330
bulkstats collector collectorIndex
[ collect-mode { auto-xfer | on-file-full | manual-xfer } | description descrip |
interval intrvl | max-size maxSize | primary-receiver primRecvIndex |
secondary-receiver secRecvIndex | single-interval ]
no bulkstats collector collectorIndex [ collect-mode | description | interval | max-size
|primary-receiver | secondary-receiver | single-interval ]*
Command introduced before JunosE Release 7.1.0.
Creates and configures a collector of bulk statistical data to collect MIB-2 ifTable MIB
objects. You can configure up to six collectors. The no version restores the default value
for specified options; if no options are specified, the no version deletes the collector.
collectorIndex—Number in the range 1–65535 that identifies the particular data collector
collect-mode—Specifies one of the following collection modes:
auto-xfer—Agent automatically transfers file when interval expires
on-file-full—Agent automatically transfers file when it is full
manual-xfer—Router or user-initiated transfers; default collection mode
descrip—Descriptive information to insert into the bulkstats file
intrvl—Time period in the range 300– 86400 seconds for which the collector transfers
data from the router to the receivers; default interval is 360 seconds
maxSize—Maximum size of the file in the range 10240–20971520 bytes; default file
size is 2,621,440 bytes
primRecvIndex—Number in the range 1–65535 that identifies the primary receiver to
which the router transfers the data; by default the primary receiver is cleared
secRecvIndex—Number in the range 1–65535 that identifies the secondary (backup)
receiver to which the router transfers the data; by default the secondary receiver is
cleared
single-interval—Specifies that the collector retrieves the bulk statistics data only once;
by default, the collector receives the data periodically
*—Indicates that one or more parameters can be repeated multiple times in a list in
the command line