Delta-Sampling - Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - COMMAND REFERENCE A TO M 2010-10-19 Command Reference Manual

Software for e series broadband services routers command reference a to m
Table of Contents

Advertisement

delta-sampling

Syntax
Release Information
Description
Options
Mode
Copyright © 2010, Juniper Networks, Inc.
delta-sampling [ discontinuity-id mibId
| discontinuity-id-type { timeStamp | timeTicks } ]
no delta-sampling [ discontinuity-id ]
Command introduced before JunosE Release 7.1.0.
Specifies delta sampling for the trigger you are configuring. The no version returns the
trigger to the default sampling method—absolute-value sampling.
discontinuity-id—Specifies a discontinuity MIB ID for the sample. The discontinuity MIB
ID monitors the sample for any discontinuity errors during the sample frequency. If a
discontinuity error occurs, the router removes the sampling for that interval.
mibId—Object ID of the discontinuity MIB attribute that you want to use for this trigger
discontinuity-id-type—Specifies a discontinuity ID type (either timeStamp or timeTicks).
The discontinuity ID type indicates the time value that you expect for a specific sample.
SNMP Trigger Configuration