ip flow-sampling-mode packet-interval
Syntax
Release Information
Description
Options
Mode
798
ip flow-sampling-mode packet-interval intervalValue
no ip flow-sampling-mode packet-interval
Command introduced before JunosE Release 7.1.0.
Defines the sampling interval for an interface that is running J-Flow. Even though each
flow is sampled, the flow sample is not necessarily cached because of system constraints.
The no version returns the sampling interval to the default value.
NOTE: For interfaces on the ES2 10G LM with either the ES2-S1 GE-8 IOA or
the ES2-S2 10GE PR IOA on E120 routers and E320 routers, J-Flow adjusts
the maximum sampling interval to 8,388,608 (decimal equivalent of
0x800000) and changes the sampling interval to the closest integer that is
a power of two and that is less than or equal to the configured value.
intervalValue—Sampling interval, in the range 1–4000000000 packets; default value
is 4000000000