Avaya DEFINITY Server CSI Maintenance Manual page 738

Table of Contents

Advertisement

Maintenance Objects
Table 75. TEST #258 ISDN Test Call — Continued
Error
Test
Code
Result
1020
ABORT
TN230x circuit-pack problem
1024
ABORT
Maintenance/Test Digital Port in use
1113
ABORT
Signaling link failed
1116
ABORT
Switch could not change the service state
1117
ABORT
ISDN service message outstanding
1118
ABORT
Far-end not administered
1119
ABORT
Test call aborted, normal call attempted
1120
ABORT
Trunk OUT-OF-SERVICE/FAR-END
1122
ABORT
No test-line number for the far-end switch
1123
ABORT
No Feature Access Code administration for this Facility Test
738
Issue 5 October 2002
Description/Recommendation
1. See the
''ATM-INTF (TN2305/6)''
1. Wait until yellow and green LEDs on the Maintenance/Test circuit pack
are OFF.
2. Rerun the test.
3. If the problem persists, see the M/T-DIG (Maintenance/Test Digital Port)
maintenance object.
1. Check the results of Test #255 (Signaling Link State Check Test).
1. See if calls are active. Run status trunk grp#/mbr#.
2. If a call is active, proceed as for Error Code 1119.
3. If a call is not active, check the Error and Alarm Logs and refer to the
ATM-TRK (Circuit Emulation Service Circuit Pack) maintenance object.
1. Wait 2 minutes and try again.
1. Check the administration of the far-end of the ATM trunk. Run status
trunk grp#/mbr#.
2. Try the test again.
1. Wait for the call to terminate normally or drop it by running busyout
trunk grp#/mbr#.
2. When the trunk is idle, retry the test.
1. Try to change the service state via Test #256 (Service State Audit Test).
2. Try the test again.
1. Check the Trunk Group Administration form.
1. Check the Dial Plan and Feature Administration forms.
maintenance object.
Continued on next page
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents