j. Error Type 3585: ISDN RESTART message received. Active calls have
been dropped.
The following Aux Data values (Error Type 3585 only) below represent the
trunk's ISDN call state at the time Error 3585 occurred. This information
can be useful if users report dropped calls on the ISDN-PRI trunks.
0
10
4
7
8
260 263
1
3
6
9
265
11
12
19
531 267 268
k. Error Type 3841: the far-end rejected an ATM CES trunk selected by the
near-end 10 times. The ATM CES trunk may not be administered on the
far-end.
1. Get the physical name of the ATM trunk by noting the decimal
2. Check administration for the named trunk on the far-end.
3. If problems persist, busyout the ATM trunk to take it out of the hunt
The WARNING alarm retires automatically whenever a called endpoint
answers an outgoing or incoming call that uses the alarmed trunk.
732
Issue 5 October 2002
Aux
Data
An idle trunk received a restart.
An ISDN RESTART from the far-end has unexpectedly cleared a
call in the ACTIVE state (call stable, parties talking).
An ISDN RESTART from the far-end has unexpectedly cleared a
RINGING call.
An ISDN RESTART from the far-end has unexpectedly cleared a
call before the call entered the RINGING state.
An ISDN RESTART from the far-end has unexpectedly cleared a
call that was already in the process of clearing.
If this condition occurs frequently, the far-end may be trying to
clear trunks that appear to be in the "hung" state.
number in the Aux Data field.