Maintenance Objects
Error Log Entries and Test to Clear Values
Table 70. ATM-BCH Error Log entries
Error
Aux
Type
Data
0 (a)
0
Any
1(b)
Any
None
18
0
busyout trunk grp/mbr
129 (c)
None
130 (d)
257(e)
Any
Service State Audit (Test
#256)
513(f)
Any
None
769(g)
Any
Service State Audit (Test
#256)
1793(h)
Any
None
3073(i)
Any
Service State Audit (#256)
3585(j)
Any
None
3841(k)
Any
None
Notes:
a.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
b. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
When running the Short Test Sequence, pay close attention to the results
of the Call State Audit Test (#257).
730
Issue 5 October 2002
Associated Test
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
Outgoing call renegotiated by the far end to another B-channel in
the absence of SETUP message glare
Near end attempted a call on a B-channel that the far end has
marked OOS
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSppp
test port UUCSSppp
release trunk grp/mbr
WNG
OFF
test port UUCSSppp
test port UUCSSppp
test port UUCSSppp
WNG
OFF
test port UUCSSppp
test port UUCSSppp
test port UUCSSppp
test port UUCSSppp
none
WNG
OFF
none
Continued on next page