Maintenance Objects
Table 65. TEST #206 Playback Speech Memory Array (PSMA) Test — Continued
Error
Test
Code
Result
1 to 254
FAIL
255
FAIL
PASS
720
Issue 5 October 2002
Description/ Recommendation
Test failed. The error code indicates the number of byte count errors found
by the Tone Detector.
1. Reset the circuit pack with reset board PCSS and run this test again. If
the test continues to fail, replace the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this test failing,
replace the circuit pack even if Step 1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. Refer to
Maintenance procedure.
Test failed. The Announcement Port and the Tone Detector never
synchronized. Check for active GPTD-PT errors, and refer to "GPTD-PT
[General Purpose Tone Detector Port (CPTR)]" Maintenance
documentation to diagnose them first.
1. If there are no active GPTD-PT errors, reset the circuit pack with reset
board PCSS and run this test again. If the test continues to fail, replace
the circuit pack (see Warning).
2. If there are recurring alarms on this port caused by this test failing,
replace the circuit pack even if Step 1 works (see Warning).
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements. Refer to
Maintenance procedure.
This port can cleanly play announcements. User-reported troubles on this
pack should be investigated using other port and circuit pack tests. Refer to
''ANN-BD (Announcement Circuit Pack)''
tests.
''General Notes''
near the beginning of this
''General
Notes''near the beginning of this
for a description of the circuit pack