Avaya DEFINITY Server CSI Maintenance Manual page 676

Table of Contents

Advertisement

Maintenance Objects
Error log entries and test to clear values
Table 3-1. Analog line error log entries
Error
Aux
Type
Data
1
0
0
1(a)
40960
40975
40977
15(b)
Any
18
0
130(c)
257(d)
40973
513(e)
769
1025
1281
1537
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warnings based on the values in set options.
676
Issue 5 October 2002
Associated
Alarm
Test
Level
Any
Any
none
Audits and
Updates Test
(#36)
busy station
WRN
extension
None
WRN
none
Station
WRN
Present Test
(#48)
Battery Feed
MIN/
2
Test (#35)
WRN
Looparound
MIN/
2
Test (#161)
WRN
Conference
MIN/
2
Test (#7)
WRN
NPE
MIN/
2
Crosstalk
WRN
Test (#6)
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
ON
release station extension
ON
test port UUCSSpp sh
OFF
test port UUCSSpp sh r 2
ON
test port UUCSSpp sh r 2
ON
test port UUCSSpp l r 2
ON
test port UUCSSpp l r 2
ON
test port UUCSSpp l r 2
555-233-119