Maintenance Objects
Hardware Error Log Entries and Test to Clear
Values
Table 56. Announcement Circuit Pack Error Log Entries
Error
Aux
Type
Data
1
0
0
Any
1 (a)
0
Circuit pack
removed or SAKI
Test (#53)
2 (o)
None
14 (b)
1 to 64
Announcement
Checksum Test
(#209)
18
0
busyout board
PCSS
23 (c)
0
None
125 (d)
None
170
0
None
217 (e)
0
None
257
65535
Control Channel
Test (#52)
257 (f)
Any
None
267 (e)
0
None
513 (g)
Any
None
1025 (h)
4363
NPE Audit Test
(#50)
1281 (i)
17699
None
1538 (j)
Any
None
1793
Angel-SP
Handshake Test
(#208)
17680
In-line Error
2049
Clock Match
(k) (l)
Inquiry Test (#212)
17674
In-line Error
698
Issue 5 October 2002
Alarm Level
(See WARNING
Associated Test
message below)
Any
MINOR
WARNING
WARNING
MINOR
MINOR
WARNING
MINOR
WARNING
MINOR
MINOR
MINOR
On/Off
Board
Test to Clear Value
Any
test board PCSS sh r 1
ON
OFF
release board PCSS
OFF
ON
ON
OFF
ON
test board PCSS l r 20
OFF
test board PCSS l
ON
ON
test board PCSS l r 3
ON
test board PCSS sh r 3
Continued on next page
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?