Avaya DEFINITY Server CSI Maintenance Manual page 687

Table of Contents

Advertisement

AN-LN-PT (Analog Line Port)
Table 53. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Test
Code
Result
0
NO
BOARD
555-233-119
Description/ Recommendation
The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use list
configuration and resolve any problems.
2. If the board is correctly inserted, use busy board UUCSS.
3. Issue reset board UUCSS.
4. Issue release board UUCSS.
5. Issue test board UUCSS long. This re-establishes the link between
the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is
inserted.
Continued on next page
Issue 5 October 2002
687