ANN-BD (Announcement Circuit Pack)
Table 56. Announcement Circuit Pack Error Log Entries — Continued
Error
Aux
Type
Data
2305
140AY Loop
Around Test (#210)
2561
Super Frame
Match Inquiry Test
(#211)
17676
In-line Error
2817 (k)
Announcement
Checksum Test
(#209)
17682
In-line Error
17699
In-line Error
(m)
3840(m)
Any
None
3999 (n)
Any
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
!
WARNING:
Announcement circuit pack alarms are upgraded to MAJOR when the BASE
Tone Generator is set to 12 (France).
Notes:
a. Error Type 1
functioning or it was physically removed from the system.
555-233-119
Alarm Level
(See WARNING
Associated Test
message below)
MINOR
MINOR
MINOR
This error indicates the circuit pack totally stopped
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
On/Off
Board
Test to Clear Value
ON
test board PCSS sh r 3
ON
test board PCSS sh r 3
ON
test board PCSS sh r 3
Continued on next page