ANN-PT (Announcement Port)
Hardware Error Log Entries and Test to Clear
Values
Table 63. Announcement Port Error Log Entries
Error
Aux
Type
Data
Associated Test
0 (a)
0
Any
1
Playback Speech
Memory Array
(PSMA) Test
(#206)
18
0
The port was
busied out
130(b)
None
Channel
Administration
Memory Array
257
(CAMA) Test
(#205)
17667
In-line error
140AY Channel
Sanity Inquiry Test
513
(#222)
17684
In-line error
769(c)
None
Notes:
a.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
b. Error type 130 indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. Error type 769 is logged and the port is alarmed when an alarm is raised on
the Announcement circuit pack because of a faulty condition with a
common circuit pack resource. Any one of the following alarmed errors on
the Announcement circuit pack causes this error to be logged against the
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD
(Announcement Circuit Pack) Maintenance documentation to resolve these
alarms. When the corresponding circuit pack alarm is cleared, this alarm
clears.
555-233-119
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
ON
MINOR
ON
MINOR
ON
Test to Clear Value
test port PCSSpp sh r 1
test port PCSSpp sh r 3
release port PCSSpp
test port PCSSpp sh
test port PCSSpp l r 3
test port PCSSpp sh r 3
Continued on next page