Avaya DEFINITY Server CSI Maintenance Manual page 700

Table of Contents

Advertisement

Maintenance Objects
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, follow the instructions for "Red (alarm)" in
Table
!
b. Error Type 14
fails, this error is logged. The Aux Data indicates the number of the first
defective announcement found. This number corresponds to the
announcement numbers on the announcement form. The extension
relating to the announcement can be determined by display
announcement. This error only appears in the Error Log in conjunction
with Error Type 2817. Follow the procedures for Error Type 2817 to
troubleshoot Error Type 14.
c. Error Type 23
physically installed. The alarm is cleared when the circuit pack is installed.
d. Error Type 125
circuit pack is logically administered. To resolve this problem, either
remove the wrong circuit pack and insert the logically administered circuit
pack OR use change circuit-pack to readminister this slot to match the
circuit pack inserted.
e. Error Type 217 and 267
Announcement circuit pack inserted in the system. Remove the alarmed
circuit pack.
f. Error Type 257
with this circuit pack. This error is not service-affecting and no action is
required.
g. Error Type 513
4352 to 4358, indicates the circuit pack has reported a hardware failure on
the circuit pack. The circuit pack should be replaced.
!
700
Issue 5 October 2002
9,
Control and Port Circuit Pack Status
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
WARNING:
Reseating and/or replacing the circuit pack results in loss of
integrated announcements (TN750/B only). See
near the beginning of this Maintenance procedure.
Whenever the Announcement Checksum Test (#209)
The circuit pack has been logically administered but not
A wrong circuit pack is inserted in the slot where this
Indicate that there is more than one TN750
This error indicates transient communication problems
This error, when reported with Aux Data in the range of
WARNING:
Replacing the circuit pack results in loss of integrated
announcements (TN750/B only). See
beginning of this Maintenance procedure.
LEDs.
''General Notes''
''General Notes''
near the
555-233-119