20.4.9
TIM6 register map
TIMx registers are mapped as 16-bit addressable registers as described in the table below:
Register
Offset
name
TIMx_CR1
0x00
Reset value
TIMx_CR2
0x04
Reset value
0x08
TIMx_DIER
0x0C
Reset value
TIMx_SR
0x10
Reset value
TIMx_EGR
0x14
Reset value
0x18-
0x20
TIMx_CNT
0x24
Reset value
0
TIMx_PSC
0x28
Reset value
TIMx_ARR
0x2C
Reset value
Refer to
Table 72. TIM6 register map and reset values
Section 2.2 on page 40
Reserved
Reserved
0
0
0
0
1
1
for the register boundary addresses.
RM0366 Rev 5
Basic timers (TIM6)
0
0
MMS
[2:0]
0
0
0
CNT[15:0]
0
0
0
0
0
0
0
0
0
PSC[15:0]
0
0
0
0
0
0
0
0
0
ARR[15:0]
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1