RM0366
Table 68. Output control bits for complementary OCx and OCxN channels with break feature
Control bits
MOE bit OSSI bit OSSR bit CCxE bit CCxNE bit OCx output state
1
X
0
0
1
1. When both outputs of a channel are not used (control taken over by GPIO controller), the OISx, OISxN, CCxP and CCxNP
bits must be kept cleared.
Note:
The state of the external I/O pins connected to the complementary OCx and OCxN channels
depends on the OCx and OCxN channel state and GPIO control and alternate function
registers.
X
0
0
0
0
1
0
1
0
X
1
1
1
0
1
1
1
0
X
X
0
0
0
1
X
1
0
1
1
General-purpose timers (TIM15/TIM16/TIM17)
(TIM15)
Output Disabled (not driven by the timer: Hi-Z)
OCx=0
OCxN=0, OCxN_EN=0
Output Disabled (not driven
by the timer: Hi-Z)
OCx=0
OCxREF + Polarity
OCx=OCxREF XOR CCxP
OCREF + Polarity + dead-
time
Off-State (output enabled
with inactive state)
OCx=CCxP
OCxREF + Polarity
OCx=OCxREF xor CCxP,
OCx_EN=1
Output disabled (not driven by the timer: Hi-Z)
Off-State (output enabled with inactive state)
Asynchronously: OCx=CCxP, OCxN=CCxNP
Then if the clock is present: OCx=OISx and OCxN=OISxN
after a dead-time, assuming that OISx and OISxN do not
correspond to OCX and OCxN both in active state
RM0366 Rev 5
(1)
Output states
OCxN output state
OCxREF + Polarity
OCxN=OCxREF XOR CCxNP
Output Disabled (not driven by
the timer: Hi-Z)
OCxN=0
Complementary to OCREF (not
OCREF) + Polarity + dead-time
OCxREF + Polarity
OCxN=OCxREF XOR CCxNP
Off-State (output enabled with
inactive state)
OCxN=CCxNP, OCxN_EN=1
547/874
574