RM0366
Bit 23 TEIF6: Transfer error (TE) flag for channel 6
0: No TE event
1: A TE event occurred.
Bit 22 HTIF6: Half transfer (HT) flag for channel 6
0: No HT event
1:An HT event occurred.
Bit 21 TCIF6: Transfer complete (TC) flag for channel 6
0: No TC event
1: A TC event occurred.
Bit 20 GIF6: Global interrupt flag for channel 6
0: No TE, HT, or TC event
1: A TE, HT, or TC event occurred.
Bit 19 TEIF5: Transfer error (TE) flag for channel 5
0: No TE event
1: A TE event occurred.
Bit 18 HTIF5: Half transfer (HT) flag for channel 5
0: No HT event
1: An HT event occurred.
Bit 17 TCIF5: Transfer complete (TC) flag for channel 5
0: No TC event
1: A TC event occurred.
Bit 16 GIF5: global interrupt flag for channel 5
0: No TE, HT, or TC event
1: A TE, HT, or TC event occurred.
Bit 15 TEIF4: Transfer error (TE) flag for channel 4
0: No TE event
1: A TE event occurred.
Bit 14 HTIF4: Half transfer (HT) flag for channel 4
0: No HT event
1: An HT event occurred.
Bit 13 TCIF4: Transfer complete (TC) flag for channel 4
0: No TC event
1: A TC event occurred.
Bit 12 GIF4: global interrupt flag for channel 4
0: No TE, HT, or TC event
1: A TE, HT, or TC event occurred.
Bit 11 TEIF3: Transfer error (TE) flag for channel 3
0: No TE event
1: A TE event occurred.
Bit 10 HTIF3: Half transfer (HT) flag for channel 3
0: No HT event
1: An HT event occurred.
Bit 9 TCIF3: Transfer complete (TC) flag for channel 3
0: No TC event
1: A TC event occurred.