Maintenance Objects
Error Log Entries and Test to Clear Values
Error
Aux
Type
Data
0(a)
0
1(c)
40987
1(d)
1 to 20
15(e)
Any
18(f)
0
23(g)
0
130(h)
257(i)
40971
513(j)
Any
1537(k)
40968
1793
2049
2305(l)
40967
3840(m)
40965
3840(n)
41029
Notes:
a.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
b.
Minor alarms may be downgraded to Warning alarms based on the values in set
options.
c. The user may experience a noisy port or link. This is an off-board problem
that is detected by the port circuit. If this problem exists, replace the circuit
pack (see caution at the beginning of this section). Once the problem is
resolved, the alarm is retired after a predetermined time.
d. At least 15 off-board problems have been detected with the link to the voice
port. When an error with the link is detected, an on-board counter is
incremented. Also see Note a, above.
e. This is an internal type error that occurs when an audit request fails.
f. The port is busied-out by command. Use release port PCSSpp to release
the port.
624
Issue 5 October 2002
Associated
Test
Any
None
None
None
busyout port PCSSpp
None
None
None
None
None
Voice and Control
Local Loop TEST
(#13)
NPE Crosstalk
Test (#9)
None
None
None
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
OFF
WARNING
ON
WARNING
OFF
MIN/
ON
WRN(b)
MIN/
ON
WRN(b)
Test to Clear Value
test port PCSSpp sh r 1
release port PCSSpp
test port PCSSpp sh
test port PCSSpp l r 3
test port PCSSpp l r 3
555-233-119