Maintenance Commands

test synchronization

Use test synchronization to update all the boards with the correct
synchronization source and parameters. The system sends a downlink message
to the tone clock and DS1 boards to place them in the correct synchronization
configuration, providing error-free digital communication between the switch and
other PBXs, COs, or customer premise equipment.
Action/
Object
Qualifier
test synch
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
590
Issue 5 October 2002
Qualifier Description
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
1
sequence fails.
Use the screen to schedule execution of
the command. The command is placed
in the command queue and is executed
at the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
Examples:
test synchronization r 3
test synchronization sh r 1
test synchronization sh r 1 schedule
test synchronization l
Logins
Defaults
init
Test
inads
Sequence
craft
= short;
Repeat =
1
2
Feature
Interactions
none