ADX16A-PT (AUDIX Analog Line/Control Link)
Table 34. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
2000
ABORT
2012
ABORT
2100
ABORT
Any
FAIL
PASS
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function.
Table 35. TEST #7 Conference Circuit Test
Error
Test
Code
Result
ABORT
Could not allocate the necessary system resources to run this test. (a)
1000
ABORT
System resources required to run test are not available. The port may be
busy with a valid call. Use display port PCSSpp to determine the station
extension. Use status station to determine the service state of the port. If the
port is in use, wait until it is idle before retesting.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
Use display port PCSSpp to determine the station extension. Use status
station to determine the service state of the port. If the port is in use, wait
until it is idle before testing.
555-233-119
Description/ Recommendation
Response to the test request was not received within the allowable time
period.
System could not respond to this request.
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Description/Recommendation
1. Retry the command at 1-minute intervals a maximum of 5 times.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Continued on next page
Issue 5 October 2002