Test Tone-Clock - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands

test tone-clock

Use test tone-clock to run hardware diagnostic tests on a tone or clock circuit
pack.
Action/
Object
Qualifier
test
location
tone-clock
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
596
Issue 5 October 2002
Qualifier Description
PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
1
sequence fails.
Use the screen to schedule execution of
the command. The command is placed
in the command queue and is executed
at the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
Logins
Defaults
init
Test
inads
Sequence
craft
= short;
Repeat =
1
2
Feature
Interactions
none