Anl-24-L (24-Port Analog Line) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

ANL-24-L (24-Port Analog Line)

ANL-24-L (24-Port Analog Line)
MO Name (in Alarm Log)
ANL-24-L
ANL-24-L
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.); and pp is the 2-digit port number (for example, 01).
The 24-Port Analog Line circuit pack (TN793) provides 24 ports for voice
terminals and supports both on-premises and off-premises analog voice
terminals.
No maintenance of the terminal connected to the 24-Port Neon Analog Line circuit
pack is performed, except to determine whether or not the terminal is connected.
Failures of the neon message waiting lamp power and the common ringing
application circuitry are reported as part of common port circuit pack errors. See
errors 1281 and 1793 in the "XXX-BD (Common Port Circuit Pack)" section.
NOTE:
This analog line circuit pack supports analog data modules. When assigned,
analog data modules provide access to the Net Pkt (TN2401/TN794) data
ports. To activate an analog data module, assign the port location on the
data form and connect a modem to the port. (The analog data module may
be used for connection to a CDR output or other adjuncts as needed.)
These ports are tested the same as all other analog ports on the circuit
pack.
555-233-119
Alarm Level
Initial Command to Run
MIN
test port PCSSpp l
WRN
test port PCSSpp sh
1
Full Name of MO
24-Port Analog Line
24-Port Analog Line
Issue 5 October 2002
639

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents