test station
Output
The following screen is an example of the output from test station 81902 short,
with the assumptions that port in cabinet 1, carrier c, slot 7, circuit 1 is an analog
port and extension 81902 is connected to that port. The responses appear on a
test-by-test basis with one line of data for each test result.
test station 81902 short
Port
Maintenance Name
01C0701
ANL-LINE
01C0701
ANL-LINE
01C0701
ANL-LINE
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
555-233-119
Alt. Name Test No. Result
The port address: cabinet-carrier-slot-circuit
The type of maintenance object that is being tested.
Alternate means of identifying the maintenance object. This field
contains the extension when the object is a station.
Test being executed
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
TEST RESULTS
35
PASS
48
PASS
36
PASS
Issue 5 October 2002
Error Code
589