Maintenance Objects
ADX8D-BD (AUDIX Circuit Pack)
MO Name (in
Alarm Log)
ADX8D-BD
MINOR or WARNINGS
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.).
The ADX8D-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack operating in digital-port (DP) mode. For circuit pack problems,
see "XXX-BD (Common Port Circuit Pack)". Port level problems are covered by
ADX8D-PT.
EMBEDDED AUDIX consists of 2 circuit packs that occupy 4 slots in a port
cabinet. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
612
Issue 5 October 2002
Alarm Level
Initial Command To Run
test board PCSS sh
1
Full Name of MO
AUDIX Circuit Pack
555-233-119
Need help?