Anl-Line (8-Port Analog Line), Anl-Ne-L (8-Port Neon Analog Line) - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Objects
ANL-LINE (8-Port Analog Line),
ANL-NE-L (8-Port Neon Analog Line)
MO Name (in Alarm
Log)
ANL-LINE
ANL-LINE
ANL-NE-L
ANL-NE-L
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.); and pp is the 2-digit port number (for example, 01).
The 8-Port Analog Line circuit packs are:
TN742
TN769
TN467
These circuit packs provide 8 ports for single line on-premises or off-premises
analog endpoints such as analog voice terminals, queue warning level lamp,
recorded announcements, dictation machines, PagePac
external alerting devices, modems, facsimile machines, and AUDIX voice ports.
The TN769 supports a neon message waiting lamp. The other 8-port analog lines
do not support the lamp.
Test #48 applies momentary ringing voltage to terminal equipment and monitors
resulting current flow to determine whether the equipment is connected to the
port. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the user or the phone equipment, to disable Test #48
use change station
releases, this will also disable Tests #6, 7, 161, and 35.
Test #47 may cause a false alarm when the port is connected to off-premises
equipment, some non-voice terminal equipment, and some loop equipment. If this
is the case, disable the test using the Tests field of the change station
command.
No maintenance of the terminal connected to the 8-Port Analog Line circuit pack
or 8-Port Neon Analog Line circuit pack is performed, except to determine
whether or not the terminal is connected. Failures of the neon message waiting
lamp power (for ANL-NE-L only) and the common ringing application circuitry are
reported as part of the Common Port Circuit Pack errors (see errors 1281 and
1793 in the XXX-BD (Common Port Circuit Pack) Maintenance documentation).
656
Issue 5 October 2002
Alarm Level
Initial Command to Run
MIN
test port PCSSpp l
WRN
test port PCSSpp sh
MIN
test port PCSSpp l
WRN
test port PCSSpp sh
and set the Tests field to n. On some software
extension
1
Full Name of MO
8-Port Analog Line
8-Port Analog Line
8-Port Neon Analog Line
8-Port Neon Analog Line
paging equipment,
extension
555-233-119

Hide quick links: