Maintenance Objects

ALARM-PT (ALARM PORT)

MO Name (in Alarm Log)
ALARM-PT
ALARM-PT
1.
Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01, 02,
etc.); and pp is the 2-digit port number (for example, 01).
The Alarm Port maintenance object provides on-board maintenance for an analog
line port that is administered as an external device alarm port. Tests are provided
to verify the analog line port's ability to detect an external device alarm. The
External Device Alarm (EXT-DEV) maintenance object is used for the off-board
external device alarm.
638
Issue 5 October 2002
Alarm Level
Initial Command to Run
MIN
test port PCSSpp l
WRN
test port PCSSpp sh
1
Full Name of MO
Alarm-Port
Alarm-Port