ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Table 48. TEST #47 Loop Around and Conference Test
Error
Test
Code
Result
ABORT
7
ABORT
1000
ABORT
1002
ABORT
1003
ABORT
1004
ABORT
555-233-119
Description/ Recommendation
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The port was seized by a user for a valid call.
1. Use display port PCSSpp to determine the station's extension. Use
status station extension to determine the service state of the port. If
the port is in use, it is unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
System resources required to run this test were not available. The port may
be busy with a valid call. (This could be a Music-on-Hold port.)
1. Use display port PCSSpp to determine the station's extension. Use
status station extension to determine the service state of the port. If
the port is in use, it will be unavailable for certain tests. Wait until the
port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to "TTR-LEV
(TTR Level)" Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to "TONE-PT
(Tone Generator)" Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
The port has been seized for a valid call during the conference or noise test.
Use status station to determine when the port is available for testing.
1. If the circuit pack is a TN742 with vintage 10 or less, this test is not
valid. Otherwise, go to Step 2.
2. When the port is available for testing, retry the command at 1-minute
intervals a maximum of 5 times.