Test Pri-Endpoint - Avaya DEFINITY Server CSI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands

test pri-endpoint

Use test pri-endpoint to run hardware diagnostic tests on all port circuits
(B-channels) that are associated with the specified PRI endpoint.
Action/
Object
Qualifier
test
extension
pri-endpoint
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
580
Issue 5 October 2002
Qualifier Description
PRI endpoint extension to be tested
(must conform to dial-plan)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
1
sequence fails.
Use the screen to schedule execution
of the command. The command is
placed in the command queue and is
executed at the specified time. The
information displayed by the command
is sent to the system printer instead of
2
the screen.
Examples:
test pri-endpoint 25012
test pri-endpoint 45002 sh
test pri-endpoint 45892 l
test pri-endpoint 24389 sh r 4
test pri-endpoint 34899 l r 6
test pri-endpoint 34912 l r 5
schedule
test pri-endpoint 93483 r 2
test pri-endpoint 10022 c
test pri-endpoint 92349 schedule
Feature
Logins
Defaults
Interactions
init
Test
none
inads
Sequence
craft
= short;
nms
Repeat = 1
555-233-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents