Maintenance Objects
Table 40. TEST #35 Battery Feed Test — Continued
Error
Test
Code
Result
PASS
The port's battery feed chip is able to provide power to the station equipment
to detect on-/off-hook, but may not be able to supply power for touch-tones. If
touch-tones are inoperative on this station, replace the circuit pack because
this port is inoperative. User-reported troubles on this port should be
investigated by using other port tests, by examining station wiring, or by
examining the station.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
648
Issue 5 October 2002
Description/Recommendation
1. Check to ensure that the board translations are correct. Use list config
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, use busyout
board.
3. Issue reset board.
4. Issue release busy board.
5. Issue test board long. This should re-establish the linkage between the
internal ID and the port. If this is not the case, check to ensure that there
is a valid board inserted.
Continued on next page
555-233-119