Maintenance Objects
Table 48. TEST #47 Loop Around and Conference Test — Continued
Error
Test
Code
Result
1005
ABORT
1018
ABORT
2000
ABORT
2100
ABORT
7
FAIL
13
14
15
670
Issue 5 October 2002
Description/ Recommendation
The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13, 14 and 15
— TN769 vintages 3, 4 and 5
Test has been disabled via administration. The default for the
the Station screen is y. Determine why this field has been set to
station. It may be due to application Test #48, which can disturb users or
terminal operations.
1. To enable the test for the station being tested, enter change station
extension and set the
Response to the test request was not received within the allowable time
period.
System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The conference test or the noise test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
The reflective loop around with gain set to low and the 600-ohm balance
failed. This will cause noisy or unreliable connections.
The reflective loop around test (with the gain set to high, using RC balance)
failed. This could cause noisy or unreliable connections. The problem can
also be off-board, as described below.
The nonreflective loop around test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
More information follows.
Test
field to y.
Test
field on
n
for this
Continued on next page