Maintenance Objects
Table 31. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Test
Code
Result
7
FAIL
Conference Test failed on the primary channel. Some users may not notice a
disruption in service. In extreme cases, the conferencing feature may not
work at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
15
FAIL
The control channel between the processor and EMBEDDED AUDIX circuit
pack is not transmitting properly. User impact may range from no noticeable
effect to loss of use of this port. This failure could also be disruptive to other
users.
16
FAIL
The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None
FAIL
The test failed for reasons external to the EMBEDDED AUDIX circuit pack.
PASS
Voice and Control Channel Local Loop test passed. All channels are
transmitting properly.
620
Issue 5 October 2002
Description/Recommendation
1. Run circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack by using test board PCSS.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and if the test still fails, replace the AUDIX circuit pack (see
precaution at the beginning of this section).
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Continued on next page