test pri-endpoint
Output
The following output example is for test pri-endpoint 22501 and assumes that
the PRI endpoint ports for extension 22501 are in cabinet 1, carrier B, slot 20,
circuits 1 to 3. The responses appear on a port-by-port and test-by-test basis with
one line of data for each test result.
test pri-endpoint 22501 short
Port
Maintenance Name
01B2001
PE-BCHL
01B2001
PE-BCHL
01B2001
PE-BCHL
01B2001
PE-BCHL
01B2002
PE-BCHL
01B2002
PE-BCHL
01B2002
PE-BCHL
01B2002
PE-BCHL
01B2003
PE-BCHL
01B2003
PE-BCHL
01B2003
PE-BCHL
01B2003
PE-BCHL
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
555-233-119
TEST RESULTS
Alt. Name Test No. Result
22501
22501
22501
22501
22501
22501
22501
22501
22501
22501
22501
22501
The port address (cabinet-carrier-slot-circuit)
The maintenance object name (PE-BCHL)
The specified extension number of the PRI endpoint.
The actual test being executed
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
36
PASS
255
PASS
256
PASS
257
PASS
36
PASS
255
PASS
256
PASS
257
PASS
36
PASS
255
PASS
256
PASS
257
PASS
Issue 5 October 2002
page 1 of 1
Error Code
581