Maintenance Commands
test trunk
Use test trunk to run hardware diagnostic tests on an entire trunk group or an
individual trunk group member, depending on the options entered.
Action/
Object
Qualifier
Qualifier Description
test
group
Administered group number (1-99)
trunk
number
member
Administered number identifying a
number
particular trunk within a trunk group (1-99).
short
Command executes a series of
nondestructive diagnostic tests.
long
Command executes a more comprehensive
and longer version of the both destructive
and nondestructive diagnostic tests.
repeat
How many times each test in the sequence
number
is repeated (1-100)
clear
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.
schedule
Use the screen to schedule execution of the
command. The command is placed in the
command queue and is executed at the
specified time. The information displayed by
the command is sent to the system printer
instead of the screen.
Examples:
test trunk 78 l
test trunk 80/1 sh r 2
test trunk 78/2 l r 25
test trunk 78/2 l r 25 schedule
test trunk 80
test trunk 80 schedule
test trunk 78 r 4
test trunk 78 c
1
If no alarms are registered against the maintenance object then the test sequence will be exercised only once.
The long clear option forces a clear of all alarms if no errors are encountered during testing. The short clear
option only clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
598
Issue 5 October 2002
1
2
Feature
Logins
Defaults
Interactions
init
Test Seq. =
none
inads
short;
craft
Repeat = 1
cust
555-233-119
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?
Questions and answers