test port
Output
The following example is the output for test port. It shows that the port in cabinet
1, carrier c, slot 7, circuit 1 is an analog port. The responses appear on a
test-by-test basis with one line of data for each test result.
test port 01c0701 short
Port
Maintenance Name
01C0701
ANL-LINE
01C0701
ANL-LINE
01C0701
ANL-LINE
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No
Result
Error Code
555-233-119
Alt. Name Test No. Result
Port address (cabinet-carrier-slot-circuit)
The name of maintenance object.
The alternate means of identifying the maintenance object.
If the Object is
The field contains
station
extension
trunk
xxx/yyy (xxx=trunk group, yyy= member number)
private CO line
P/xxx (xxx = private CO line group number)
Test being executed.
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
TEST RESULTS
35
PASS
48
PASS
36
PASS
Issue 5 October 2002
Error Code
579
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?