Timer Query (Igmp View) - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

undo timer other-querier-present
View
Public instance IGMP view, VPN instance IGMP view
Default Level
2: System level
Parameters
interval: IGMP other querier present interval, in the range of 60 to 300.
Description
Use the timer other-querier-present command to configure the IGMP other querier present interval
globally.
Use the undo timer other-querier-present command to restore the system default.
By default, the IGMP other querier present interval is [ IGMP query interval ] times [ IGMP querier
robustness variable ] plus [ maximum response time for IGMP general queries ] divided by two.
By default, the three parameters in the above-mentioned formula are 60 (seconds), 2 (times) and 10
(seconds) respectively, so the IGMP other querier present interval = 60 × 2 + 10 / 2 = 125 (seconds).
Related
commands:
max-response-time, display igmp interface.
Examples
# Set the IGMP other querier present interval to 200 seconds globally in the public instance.
<Sysname> system-view
[Sysname] igmp
[Sysname-igmp] timer other-querier-present 200

timer query (IGMP view)

Syntax
timer query interval
undo timer query
View
Public instance IGMP view, VPN instance IGMP view
Default Level
2: System level
igmp
timer
other-querier-present,
1-30
timer
query,
robust-count,

Advertisement