By default, the MLD querier robustness variable is 2, so the startup query count is also 2.
Related commands: mld startup-query-count, robust-count.
Examples
# Set the startup query count to 3 globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] startup-query-count 3
startup-query-interval (MLD view)
Syntax
startup-query-interval interval
undo startup-query-interval
View
MLD view
Default Level
2: System level
Parameters
interval: Startup query interval in seconds, namely, the interval between general queries the MLD
querier sends on startup, with an effective range of 1 to 18000.
Description
Use the startup-query-interval command to configure the startup query interval globally.
Use the undo startup-query-interval command to restore the system default.
By default, the startup query interval is 1/4 of the "MLD query interval".
By default, the MLD query interval is 125 seconds, so the startup query interval = 125 / 4 = 31.25
(seconds).
Related commands: mld startup-query-interval, timer query.
Examples
# Set the startup query interval to 5 seconds globally.