3Com S7906E Command Reference Manual page 1344

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

Value of other querier present interval for MLD(in seconds): 255
Value of maximum query response time for MLD(in seconds): 10
Value of last listener query interval(in seconds): 1
Value of startup query interval(in seconds): 31
Value of startup query count: 2
General query timer expiry (hours:minutes:seconds): 00:00:23
Querier for MLD: FE80::200:AFF:FE01:101 (this router)
MLD activity: 1 joins, 0 leaves
Multicast ipv6 routing on this interface: enabled
Robustness: 2
Require-router-alert: disabled
Fast-leave: disabled
Ssm-mapping: disabled
Startup-query-timer-expiry: off
Other-querier-present-timer-expiry: off
Total 1 MLD Group reported
Table 1-3 display mld group port-info command output description
Field
Ethernet1/1(FE80::200:AFF:FE01:101)
Current MLD version
MLD group policy
Value of query interval for MLD (in seconds)
Value of other querier present interval for MLD
(in seconds)
Value of maximum query response time for MLD
(in seconds)
Value of last listener query interval (in seconds)
Value of startup query interval(in seconds)
Value of startup query count
General query timer expiry
Querier for MLD
MLD activity
Robustness
Require-router-alert
Fast-leave
Ssm-mapping
Startup-query-timer-expiry
Interface name (IPv6 link-local address)
MLD version running on the interface
MLD group policy
MLD query interval, in seconds
MLD other querier present interval, in seconds
Maximum response delay for general query
messages (in seconds)
MLD last listener query interval, in seconds
MLD startup query interval, in seconds
Number of MLD general queries sent on startup
Remaining time of the MLD general query timer ,
where "off" means that the timer never times out
IPv6 link-local address of the MLD querier
MLD activity statistics (number of join and done
messages)
MLD querier robustness variable
Dropping MLD messages without Router-Alert
(enabled/disabled)
MLD fast leave processing status
(enabled/disabled)
MLD SSM mapping status (enabled/disabled)
Remaining time of MLD startup query timer ,
where "off" means that the timer never times out
1-5