Examples
# Enable automatic link cost calculation.
<Sysname> system-view
[Sysname] isis
[Sysname-isis-1] auto-cost enable

bandwidth-reference (IS-IS view)

Syntax
bandwidth-reference value
undo bandwidth-reference
View
IS-IS view
Default Level
2: System level
Parameters
value: Bandwidth reference value in Mbps, ranging from 1 to 2147483648.
Description
Use the bandwidth-reference command to set the bandwidth reference value for automatic link cost
calculation.
Use the undo bandwidth-reference command to restore the default.
By default, the bandwidth reference value is 100 Mbps.
Related commands: auto-cost enable.
Examples
# Configure the bandwidth reference of IS-IS process 1 as 200 Mbps.
<Sysname> system-view
[Sysname] isis
[Sysname-isis-1] bandwidth-reference 200

circuit-cost

Syntax
circuit-cost value [ level-1 | level-2 ]
undo circuit-cost [ level-1 | level-2 ]
View
IS-IS view
Default Level
2: System level