07/11/02 09:19:09 61TA0000_170_0013
Power Steering

Pump Pressure Test with T/N 07406-001000A or T/N 07406-001A101

Special Tools Required
• P/S joint adapter (pump) 07RAK-S040110
• P/S joint adapter (hose) 07RAK-S040122
• P/S pressure gauge 07406-001000A or 07406-001A101
Check the fluid pressure as follows to determine
whether the trouble is in the pump or steering gearbox.
1. Check the power steering fluid level (see page
17-14).
2. Disconnect the pump outlet hose (A) from the
pump outlet with care so as not to spill the power
steering fluid on the frame and other parts, then
install the P/S joint adapter (pump) on the pump
outlet (B).
*03
6 x 1.0 mm
11 N·m (1.1 kgf·m, 8.0 lbf·ft)
07406-001000A or
07406-001A101
B
3. Connect the P/S joint adapter (hose) to the P/S
pressure gauge, then connect the pump outlet hose
to the P/S joint adapter (hose).
4. Install the P/S pressure gauge to the P/S joint
adapter (pump).
17-12
5. Fully open the shut-off valve (A).
A
6. Start the engine, and let it idle.
07RAK-S040122
7. Turn the steering wheel from lock-to-lock several
8. Measure steady-state fluid pressure while the
07RAK-S040110
9. Close the shut-off valve gradually, and read the
6 x 1.0 mm
11 N·m
(1.1 kgf·m,
8.0 lbf·ft)
10. Immediately open the shut-off valve fully.
TA08AE4F24500047031FEAT20
A
times to warm the fluid to operating temperature at
158 °F (70 °C).
engine is idling. If the pump is in good condition,
the gauge should read no more than 1,470 kPa
2
(15 kgf/cm , 213 psi).
If the reading is high, check for:
• Clogged or deformed inlet or return line between
the pump and the steering gearbox.
• Clogged valve body unit.
pressure.
Do not keep the shut-off valve closed more
than 5 seconds or the pump could be
damaged by overheating.
If the pump is in good condition, the gauge should
read at least 8,140 8,820 kPa (83 90 kgf/cm ,
1,180 1,280 psi). A low reading means the pump
output is too low for full assist. Repair or replace
the pump.
2