07/11/02 09:19:23 61TA0000_140_0273
5. Connect the red hose to the cooler outlet line (the
line that normally goes to the external filter on the
transmission).
6. Connect the blue hose to the cooler inlet line.
7. Connect a shop air hose (regulated to 100 to
125 psi) to the air purge valve.
The quick-connect fitting has a one-way
check valve to keep ATF from entering your
shop's air system. Do not remove or replace
the fitting. Attach the coupler provided with
the cooler cleaner to your shop air line if
your coupler is not compatible.
8. Flip the MOTOR toggle switch to ON; the green
indicator above the toggle switch comes on. Let the
pump run for 5 minute. While the pump is running,
open and close the air purge valve periodically to
cause agitation and improve the cleaning process.
Always open the valve slowly. At the end of the
5-minute cleaning period, leave the air purge valve
open.
NOTE: While the pump is running with the air
purge valve open, it is normal to see vapor coming
from the filler/breather tube vents.
*04
9. With the air purge valve open, flip the MOTOR
toggle switch to OFF; the green indicator goes off.
Leave the air purge valve open for at least
15 seconds to purge the lines and hoses of residual
ATF, then close the valve.
10. Disconnect the red and blue hoses from the ATF
cooler. Now connect the red hose to the cooler inlet
line.
11. Now connect the blue hose to the cooler outlet line.
OPEN
CLOSED
12. Flip the MOTOR toggle switch to ON, and let the
pump run for 5 minute. While the pump is running,
open and close the air purge valve periodically.
Always open the valve slowly. At the end of the
5-minute cleaning period, leave the air purge valve
open.
NOTE: While the pump is running with the air
purge valve open, it is normal to see vapor coming
from the filler/breather tube vents.
13. With the air purge valve open, flip the MOTOR
toggle switch to OFF. Leave the air purge valve
open for at least 15 seconds to purge the lines and
hoses of residual ATF, then close the valve.
14. Disconnect the red and blue hoses from the ATF
cooler lines.
15. Connect the red and blue hoses to each other.
16. Disconnect the shop air from the air purge valve.
Disconnect and stow the coupler if used.
17. Disconnect and stow the fittings from the ATF
cooler inlet and outlet lines.
18. Unplug the cooler cleaner from the 110 V outlet.
Tool Maintenance
Follow these instructions to keep the ATF cooler cleaner
working properly:
• Replace the two magnetic nonbypass spin-on filters
once a year or when you notice a restriction in the
ATF flow.
• Check the level and condition of the fluid in the tank
before each use.
• Replace the ATF in the tank when it looks dark or dirty.
FILLER CAP
HEATER
MAGNETIC
NONBYPASS
TANK
SPIN-ON FILTER
14-271